Functional characteristics
Modular design using B/S architecture, standard rail installation
The weak current input and output share a single interface, which can press keys and backlights at the same time, simplifying the number of wiring
Up to 31 relay modules A9-R can be cascaded, and the relay modules can be opened or closed individually, working independently, and the relays do not affect each other (if one of them does not work). Other modules are not affected)
Three RS-485 buses, of which - high-speed bus for modular expansion, two for peripheral expansion
Product parameter
Name:C9
Input:DC-12V 2.5A
Working current:1.2A
Master control:ARM 32bit
Hardware protocol:i TCP/IP
NET:UTP
RS485:3Road(1A/road)
Server:Cloud and Local
Fuse: built-in replaceable
Extensible: 31 relay modules can be extended
Work temp:+5°C ~ +50°C